Price List
INFINITY® SIGNAL CONDITIONERS
RS-485 CONFIGURABLE WITH RS485 OUTPUT

PROCESS VOLTAGE OR CURRENT DRX-PR
The DRX-PR signal conditioner accepts process signal inputs within the spans of 400mV, 1, 2, 5, 10V, and 20mA. Excitation of 10 or 14Vdc @ 20mA max. is available for use with the input device. Accuracy is 0.1% with 13 bit resolution and computer scalable via RS-485 using the DRX-CONFIG software package.

PROCESS VOLTAGE OR CURRENT DRX-PR
$275.00

STRAIN GAGE/BRIDGE OR MILLIVOLT
DRX-ST The DRX-ST signal conditioner accepts strain gage/bridge or millivolt inputs with ratiometric or absolute measurement. 10V excitation is standard. Input spans of 30 or 100mV full scale. Accuracy is 0.1% with 13 bit resolution and computer scalable via RS-485 using the DRX-CONFIG software package.


STRAIN GAGE/BRIDGE OR MILLIVOLT
$300.00

THERMOCOUPLE INPUT
DRX-TC The DRX-TC signal conditioner accepts thermocouple types J, K, T, R, S, B, N and J-DIN. The analog output is configurable for 0 to 10Vdc, 0 to 20mA or 4 to 20mA. Input and output configuration is via RS-485 using the DRN-CONFIG software package. The DRX series features 3-way isolation to 1800V peak, ▒1░C accuracy and resolution to 0.3░C above -200░C.

THERMOCOUPLE INPUT
$250.00

RTD INPUT
DRX-RTD The DRX-RTD signal conditioner accepts 100, 500 or 1000 ohm RTDs with alpha of 0.00385 or 0.00392. Input and output configuration is via RS-485 using the DRX-CONFIG software package. The DRX series features 3-way isolation to 1800V peak, ▒1░C accuracy and resolution to 0.1░C.

RTD INPUT
$250.00

AC VOLTAGE INPUT
DRX-ACV The DRX-ACV signal conditioner accepts AC voltage input ranges of 400mV, 4V, 40V and 400V. Accuracy is 0.2% with 13 bit resolution and computer scalable via RS-485 using the DRX-CONFIG software package. The DRX series features 3-way isolation to 1800V peak.

AC VOLTAGE INPUT
$270.00

AC CURRENT INPUT
DRX-ACC The DRX-ACC signal conditioner accepts AC current input ranges of 10, 100mA, 1A or 5A. Accuracy is 0.2% with 13 bit resolution and computer scalable via RS-485 using the DRX-CONFIG software package. The ôDRX series features 3-way isolation to 1800V peak.

AC CURRENT INPUT
$270.00

FREQUENCY/PULSE INPUT
DRX-FP The DRX-FP signal conditioner accepts pulse inputs from NPN/PNP open collector, TTL/CMOS, magnetic and NAMUR proximity sensor outputs. Excitation of 5, 8.2 or 12.5Vdc @ 25mA is available for the transducer. Frequency (0.2-50kHz) or Totalize/Reset is standard. The Reset input can be reconfigured as a second input to support A-B or Quadrature Totalize modes.

FREQUENCY INPUT
$250.00

ACCESSORIES
DRN-PS-750
Power supply, 24Vdc @750 mA output, 115 Vac input
$130.00
DRN-PS-1000
Power supply, 24Vdc @1 A output, 95-240 Vac input
$150.00
CAT-285
Bi-directional RS-232/RS-485 converter for DRX
$148.00
DRX-CONFIG-9
Setup software with 9-pin interconnection cable
$100.00
DRX-CONFIG-25
Setup software with 25-pin interconnection cable
$100.00

INFINITY® SIGNAL CONDITIONERS
RS-232 CONFIGURABLE WITH ANALOG OUTPUT

PROCESS VOLTAGE OR CURRENT DRX-PR
The DRN-PR-C signal conditioner accepts process signal inputs within the spans of 400mV, 1, 2, 5, 10V, and 20mA. Excitation of 10 or 14Vdc @ 20mA max. is available for use with the input device. Accuracy is 0.1% with 13 bit resolution and computer scalable via RS-232 using the DRN-CONFIG software package.
PROCESS VOLTAGE OR CURRENT DRX-PR
$325.00

STRAIN GAGE/BRIDGE OR MILLIVOLT
The DRN-ST-C signal conditioner accepts strain gage/bridge or millivolt inputs with ratiometric or absolute measurement. 10V excitation is standard. Input spans of 30 or 100mV full scale. Accuracy is 0.1% with 13 bit resolution and computer scalable via RS-232 using the DRN-CONFIG software package.

STRAIN GAGE/BRIDGE OR MILLIVOLT
$345.00

THERMOCOUPLE INPUT
The DRN-TC-C signal conditioner accepts thermocouple types J. K, T, E, R, S, B, N and J-DIN. The analog output is configurable for 0 to 10Vdc, 0 to 20mA or 4 to 20mA. Input and output configuration is via RS-232 using the DRN-CONFIG software package. The DRN series features 3-way isolation to 1800V peak, ▒1░C accuracy and resolution to 0.3░C above -200░C.

THERMOCOUPLE INPUT
$325.00

RTD INPUT
The DRN-RTD-C signal conditioner accepts 100, 500 or 1000 ohm RTDs with alpha of 0.00385 or 0.00392. Input and output configuration is via RS-232 using the DRN-CONFIG software package. The DRN series features 3-way isolation to 1800V peak, ▒1░C accuracy and resolution to 0.1░C.

RTD INPUT
$355.00

AC VOLTAGE INPUT
The DRN-ACV-C signal conditioner accepts AC voltage input ranges of 400mV, 4V, 40V and 400V. Accuracy is 0.2% with 13 bit resolution and computer scalable via RS-232 using the DRN-CONFIG software package. The DRN series features 3-way isolation to 1800V peak.

AC VOLTAGE INPUT
$345.00

AC CURRENT INPUT
The DRN-ACC-C signal conditioner accepts AC current input ranges of 10, 100mA, 1A or 5A. Accuracy is 0.2% with 13 bit resolution and computer scalable via RS-232 using the DRN-CONFIG software package. The DRN series features 3-way isolation to 1800V peak.


AC VOLTAGE INPUT
$345.00

FREQUENCY/PULSE INPUT
The DRN-FP-C signal conditioner accepts pulse inputs from NPN/PNP open collector, TTL/CMOS, magnetic and NAMUR proximity sensor outputs. Excitation of 5, 8.2 or 12.5Vdc @ 25mA is available for the transducer. Frequency (0.2-50kHz) or Totalize/Reset is standard. The Reset input can be reconfigured as a second input to support A-B or Quadrature Totalize modes.

FREQUENCY INPUT
$295.00

ACCESSORIES
DRN-PS-750
Power supply, 24Vdc @750 mA output, 115 Vac input
$130.00
DRN-PS-1000
Power supply, 24Vdc @1 A output, 95-240 Vac input
$150.00
DRN-CONFIG-9
Setup software with 9-pin interconnection cable
$100.00
DRN-CONFIG-25
Setup software with 25-pin interconnection cable
$100.00


Fast Quotes on Products

HOME / PRODUCT GUIDE / TECHNICAL REFERENCE
NEWPORT Electronics, Inc. (714) 540-4914 or Contact Us
Copyright 1999, Newport Electronics, Inc. All rights reserved.